back button black v05

PLC and field bus data logging

PLC and field bus data logging

19 October 2016

Delphin Technology AG: Industry 4.0 (IoT), energy monitoring according to EN 50001 and condition monitoring are the issues of today. The applications, technologies and systems behind them form the basis for a comprehensive networking of sensors, actuators, controllers and other equipment.

Interoperability is also required from measurement technology. Analog and digital signals are now being increasingly replaced by field buses. At test stands, precision measurement data needs to be transferred to central control systems using field bus interfaces.

New energy laws also require the data acquisition, archiving and evaluation of power output, pressures, flows and many other parameters all of which are generally already available in PLC and building management systems.

All the above show that data acquisition is required not only in new systems but also in existing plant, machinery and automated building systems. Delphin hardware and software products are equipped with a range interfaces and protocols to meet these requirements.

The ProfiMessage, Expert Logger, Expert Transient and Expert Vibro devices from Delphin each have two PROFIBUS, one Modbus TCP, one CAN, and one Modbus RTU interfaces. The integrated PROFIBUS interface also supports sniffing functions. Delphin products also have an integrated OPC UA client and server to make them future ready especially regarding Industry 4.0 (IoT).

Binary and analog data from sensors, actuators and PLC systems can be transferred to Delphin devices via the interfaces and then monitored, archived and evaluated.

Furthermore, measurement data, computed data and alarms acquired by Delphin devices can be transferred to controllers via a field bus. Two-way data transfer is possible.

Special features of Delphin products when used for the above purposes

  • Combined measurement data acquisition and field bus connection
  • Synchronised acquisition of field bus and standard measurement data 
  • Two-way data transfer between data acquisition and control systems
  • Redundant PROFIBUS interface (integration using GSD file)
  • ProfiBus sniffer function (no additional slave setup required)
  • Modbus TCP, RTU master and slave, and CAN interfaces
  • NEW: OPC UA server and client available

Possible without Delphin hardware?

The powerful ProfiSignal software has a range of interfaces to enable direct data transfer with controllers and other systems and equipment. Interfaces available to ProfiSignal include an OPC server and client, a ModBus TCP and also many serial protocols. ProfiSignal is software for hands-on users who want instant measurement data that they can evaluate themselves and easily report in a Word file or export to Excel.

A multitude of applications using ProfiSignal have already been implemented in industry, in steelworks and in building control technology.

Typical applications for PLC and field bus data acquisition:

  • Fault analysis in equipment, machines and plant
  • Condition monitoring in plant and machinery 
  • Test stand automation
  • Process analysis and optimisation 
  • Energy data acquisition according to EN 50001
  • Field trials and testing 
  • Permanent monitoring and diagnoses on gas turbines
  • Monitoring of vibrations and linking to control systems 
  • Extending PLC system with data archiving and accounting

We will be happy to help you with your system with an offer for your specific measurement needs.

  • Delphin Technology AG
    Lustheide 81
    51427 Bergisch Gladbach
    Germany / Europe
    Tel.: +49 2204 97685-0
    Fax: +49 2204 97685-85
    Email: info@delphin.de
    Web : www.delphin.com
  • company website button
  • all entries button

back button black v05