back button black v05

ECcast - Eddy Current Mould Level Measurement

ECcast - Eddy Current Mould Level Measurement

07 June 2013

BERTHOLD Technologies: ECcast - Berthold's electromagnetic measurement system - measures the mould level reliably and extremely accurately, and is not affected by casting powder or slag. ECcast can be used as a stand-alone system or for even higher process reliability it can be combined with the radiometric GAMMAcast systems.

System characteristics

  • Best accuracy
  • High resolution <0.1 mm
  • Quick response time
  • Not affected by casting powder or slag
  • No radioactive source required
  • Easy retrofit of existing casters

Measuring Principle

A coil inside the sensor generates an electromagnetic field, penetrating deep into the mould. As a result eddy currents are induced in the top layer of the molten metal. These eddy currents in turn generate a counteracting electromagnetic field – its strength being proportional to the distance between sensor and molten metal inside the mould. In this way the mould level can be determined very precisely and irrespective of casting powder or slag.

Combination: ECcast plus GAMMAcast

The two technologies eddy current and nucleonic complement each other to the top system for highest demands. Benefit from

  • Large measuring range
  • Perfect automatic start-up
  • Highest safety due to redundancy
  • Possible determination of casting powder thickness

  • BERTHOLD Technologies GmbH & Co. KG
    Calmbacherstr. 22
    75323 Bad Wildbad
    Germany / Europe
    Tel.: +49 (7081) 177 0
    Fax: +49 (7081) 177 167
    Email: Industry@Berthold.com
    Web : www.Berthold.com